specifies the units of the Device co-ordinates. The base unit is micron.
Therefore, a number of 1000 indicates the scale mm is used, 25.4 means the
unit is mils. InvertXPos and InvertYPos specify whether the co-ordinates
data need to be inverted during import. Sometime the position of the Devices
on the bottom side of the PCB is represented using top side co-ordinates. In
cases such as this, inverting one of the co-ordinates during import would be
necessary. Use 1 if inversion is desired, otherwise 0. The BoardRtn field
indicates the angular difference of the co-ordinates between the CAD data
and the board being inspected. Because of the fixture limitations, it is
sometimes not possible to inspect the board in the same orientation as the
CAD data. A number of 90 in this field indicates the board being inspected is
rotated 90 degrees counter clockwise from the CAD data. The valid data in
the field are 90, 180, and 270. There is a second optional data field for this
line; it can be either 1 or -1; 1 is the default value which indicates that the
Device rotation field uses a sign convention that counter-clockwise is positive.
A value of -1 indicates that the Device rotation uses a convention that
clockwise is positive. Rot’nOffset is an offset value that will be added to all
the device rotations. The function of this offset is to match the rotation of the
CAD data to that of the Central of Shared library Device. The .DATA_START
field is a flag indicating the beginning of the Device data. This field is case
sensitive. The following line is the column label of the Device data. Device
data begins on the next line.
RefID Name X Y Rot. CamNo Package
IC1 ---- 123.3 23.45 0 0 ----
U2 74LS14 23 23 0 0 ----
R1 001-89-57 12.3 3.45 0 0 ----
C123 001-90-23 23 23 0 0 ----
...(more lines of Device data)
...
.DATA_END
At the end of the Device data there must be a flag, .DATA_END, to indicate
the end of the Device data.
Exporting
In addition to extracting information from a CAD data file, the system can also
generate a file in this format based on the information from a board setup. The
process is called Exporting. To export CAD data, select File | Export CAD
Data from the main menu.
Importing
Compared to Exporting, Importing CAD data is a much more complex
process. The process begins by the user selecting File | Import CAD File
from the main menu. The system opens the specified file to verify its format. If
the format is correct, the system prompts the user to load a board
corresponding to the CAD data into the system.
The software analyzes the Device position information from the CAD data and
positions the Image over three Devices on the board. Each time the user is