By grabbing too much of the background in combination with a low threshold setting (~550); small dark bodied
discreet components (in combination with a dark FR4 material background); may cause false calls, as there is
not be enough difference in coloration (digital information) to catch presence/absence. Using a bare board is
VERY IMPORTANT when thresholds are set below 600 to fine-tune and eliminate false-calls or escapes.
HowtoFixBadTemplates
Inspect your templates and thresholds for all parts that are failing the bare board test. Make certain that the
existing templates are as ideal as possible. It may only take one bad template to throw off the test for a specific
part type. Delete any templates that display bad structure.
Dark 0402 on Dark FR4 Delete all bad templates Never lower than 550
Top (bad template)
Bottom (better template)
AlternateROITrainingMethod
Try increasing the region of interest (ROI) to encompass more of the part body and less of the background; or
include a small portion of the solder and a tight area of background for (0402 dark on dark) device types.
NOTE: Delete any poorly created templates.