AOpen AOI-702U Spezifikationen Seite 51

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 165
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 50
FA Inspector (AOI) Scanner
51 | Page
FocalSpot, Inc. | www.FocalSpot.com
3. Load a PCB in the center of the table at (15, 20 or 25mm) stand-off height.
Best Practice: Always use the 20mm stand-off position whenever possible, as this position provides
the best focus and lighting. Maximum component clearance is 70mm at the 20mm setting.
4. Press the <15mm, 20mm or 25mm > calibration button in the File Selection/Calibration Screen that
matched the stand-off position used when the board was loaded (15, 20 or 25mm).
5. The AOI Mode Display Screen will now open in the default Operator Mode.
Note: You will need to change to Supervisor Mode to create a new inspection routine. Supervisor
Mode provides full access to development and management functions; including all of the Operator
Mode functions. Users are required to provide a password to enter Supervisor Mode.
Note Also: Multiple user accounts can be configured if operator tracking is required. See also, User
Login and Tracking for more information on this topic.
6. To enter Supervisor Mode select <File / Go to Supervisor Mode>, when prompted <Enter the
Supervisor Password>, the default password is: “focalspot”. See, Supervisor Mode for menu item
definitions.
Go to Supervisor Mode Check Password Dialog Box
Seitenansicht 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 164 165

Kommentare zu diesen Handbüchern

Keine Kommentare