1. The Device import process can be aborted at any time by pressing <Cancel> on the Confirm/Adjust
Device Position dialog box or by pressing the <Stop> button on the Top Menu Bar. Devices that have
been trained up to this point will remain in the library, <save> the file before exiting the program. See:
Save Board Setup (AOI Mode).
R
R
e
e
s
s
u
u
m
m
e
e
D
D
e
e
v
v
i
i
c
c
e
e
T
T
r
r
a
a
i
i
n
n
i
i
n
n
g
g
1. To resume the Device Training process after a session has been <Cancelled> or terminated by other
means.
2. Launch the AOI Mode software and select a saved inspection routine from the <Product> Pick List.
a. Review the Set Up Information notes to determine the PCB location on the table and standoff
height used to stage the board.
b. Load a PCB and stage it at the proper stand-off height and table grid XY location.
3. Press the <Test Board> Button. The Main Program Display Screen will now load along with all of the
setting saved for that specific inspection routine.
4. From the AOI Mode Top Menu Bar select <Scanner/Scanner Setup> to capture an image of the PCB.
5. To resume the interrupted Device Training process, you must re-import the CXF data and re-define (3)
three component XY locations again.
6. Before loading CXF Data. The scanned PCB must be re-aligned by pressing the
button to align the
board. Since the Device information in the XY Data file merges with the Device information in the board
setup, there is no danger of importing the same Device twice.
a. If the PCB is not aligned the next step “Import CXF Data” will be grayed out on the screen and
prevent this operation.
7. Select File > CXF Data > Import CXF Data from the Top Menu Bar and load the CXF file that is
associated with the selected test routine and PCB that is loaded in the system.
8. Next it is necessary to realign the XY data to the PCB image before continuing training.
9. It is a good practice for the Process Control Engineer or person creating the inspection routine
(Supervisor Mode) to enter Board Notes with any data that may be useful to the Operator (Operator
Mode) or for future reference. To create or edit Board Notes select <Edit / Create/Edit Board Notes>
from the AOI Mode Top Menu Bar. Once edited and saved, these note will be associated with a specific
PCB and be displayed (along with a scanned image of the PCB) when a test routine is selected from
the AOI Mode Production Launcher. See Create / Edit Board Notes
10. Once the three (3) XY to Image points have been confirmed, the Device Training Process should
resume from the point where the session was stopped.
NOTE: Make sure “Auto-Train Enable” is checked.