7. Next, click in either the <Centre on PN> or <Centre on PN >- Component> Pick List Text Area and
use the Keyboard <Up> and <Down> Arrow Keys to step-thru the devices.
<Device RefID> and <Part Number> Pick Lists
a. Clicking in the <Device RefID> Pick List and pressing the keyboard <Up/Down> Arrow Keys;
moves though devices by device Reference ID in alpha/numeric order.
b. Clicking in the <Part Number> Pick List and pressing the keyboard <Up/Down> Arrow Keys;
moves through devices in order of Package Type in alpha/numeric order.
c. For either method device data is presented in the <CXF Information Column> of the CXF
Display Window.
NOTE: Layout Viewer FA Mode does NOT produce an inspection routine and therefore should only be
used in cases where speed is critical and the need for follow on automated inspections are either not
necessary or can be put off for later, when time permits.
Best Practice: It is STRONGLY RECOMMENDED that First Article Inspections be performed in
AOI Mode as a standard practice. First Article Inspection using AOI Mode is only slightly more time
consuming, but produces automated test routines that can be used on all subsequent PCBAs of the
same type. However, we understand that there are rare instances were FA Mode can be useful – it is
therefore STRONGLY RECOMMENDED to use FA Mode ONLY in these special cases.